| Product | Type | Rating | Configuration |
|---|---|---|---|
| Refrigerated Air Dryer | Non-Cycling | 1,200 SCFM | Air-cooled, 460/3/60 |
-HPRN Series details
Note: unit pictured is representative of the standard HPRN Series and may not exactly depict p/n HPRN1200 as shown on this page.
Rated 1,200 SCFM at 100 psig and 100°F inlet, HPRN1200 sits in the HPRN Series of non-cycling refrigerated dryers. It connects through 4 in flange and runs on 460/3/60 and draws about 8.7 kW. Series limits: 120°F maximum inlet; 232 psig maximum inlet pressure; R-134a refrigerant; 64 x 29 x 45 in and about 810 lb. Sizing starts from actual inlet flow, inlet temperature, pressure and ambient; the correction factors on the Sizing pages show how far a nameplate rating moves under real conditions.