Desiccant Air Dryers

For dew points a refrigerated dryer cannot reach

Request a quote

Below 38°F

When refrigerated air is not dry enough

A refrigerated dryer stops at about a 38°F pressure dew point because its evaporator has to stay above freezing. That is ISO 8573-1 class 4, enough for air that never leaves a heated building. A desiccant dryer adsorbs water vapor onto activated alumina or silica gel instead, reaching -40°F, class 2, as a standard rating and -100°F, class 1, from a heatless twin tower on its shortest cycle.

Three situations call for one: pipe that runs outdoors or through an unheated dock in winter, a written requirement for class 1, 2 or 3 water, and products spoiled by humidity rather than liquid water. Everywhere else the refrigerated dryer stays, and the desiccant or membrane unit goes after it on only the air that needs the lower dew point.

Membrane dryers belong in the same decision. Hollow fibers let water vapor permeate out into a sweep stream, so there is no bed to replace, no condensate to drain and, on fixed-sweep designs, no power at all.

Regenerative twin tower dryers - heatless desiccant air dryer, representative unit

Regenerative twin tower dryers:

Two vessels of activated alumina: one dries the plant air while the other is regenerated, then they swap. These dry a compressor room or a main header, and the choice inside the family is how the off-line tower is regenerated.

  • Heatless: 40 to 5,400 SCFM, class 1, 2 or 3 by cycle time
  • Externally heated: 300 to 3,200 SCFM, up to 15% less purge than heatless
  • Blower purge: 500 to 4,300 SCFM, no purge air at design conditions
Point-of-use dryers - modular desiccant air dryer, representative unit

Point-of-use dryers:

Small dryers on one branch, one machine or one paint station, downstream of the plant's refrigerated dryer. Sizing to the branch keeps purge, price and footprint small.

  • Modular heatless: 3 to 177 SCFM, -40°F or -94°F
  • Membrane: no moving parts, flow set by the dew point you choose
  • Single tower silica gel: 5 to 30 SCFM, no electrics

Dry the plant at 38°F, then dry only the line that freezes.

Send the flow, line pressure, inlet temperature and the dew point the process names.
Request a Quote

Which dryer for which duty

Start from the coldest point the air will see and any dew point written into the process specification; the dryer type follows from those two facts.

DUTY DEW POINT NEEDED DRYER TO LOOK AT
Tools, machines and paint inside a heated building 38°F, class 4 Refrigerated; no desiccant needed
Main header feeding instrument air or an outdoor yard -40°F, class 2 Heatless or blower purge twin tower
One branch that runs outside or through a cold dock -40°F on that branch only Modular heatless after the refrigerated dryer
Pharmaceutical or electronics line with a written class 1 limit -100°F, class 1 Heatless twin tower on its 4-minute cycle
Winter freeze protection on a large system -4°F, class 3 Externally heated twin tower
HVLP spray gun or a single small tool As low as -40°F at the gun Single tower silica gel
Analyzer, enclosure or machine with no power nearby +50°F down to -40°F Membrane

Reading the dew point on a specification

Pressure dew point is the temperature at which water condenses at line pressure, and it is the figure dryer ratings use. A specification asking for -40°F atmospheric dew point wants less: roughly class 3, not class 2. Confirm which one is written before sizing, because the step from class 4 to class 2 changes the dryer type and the running cost.

What the purge costs

A heatless dryer regenerates by blowing part of its own dried air through the off-line tower to atmosphere, roughly 15 percent of rated flow. On a 500 SCFM unit that is about 75 SCFM, or 15 to 20 hp of compressor output doing no work. Heated and blower purge designs replace most of that air with electric heat, and a demand purge control trims it further whenever the plant runs below rated flow.

Filtration is part of the dryer

Oil coats desiccant and ends its life early, so every desiccant dryer needs a 0.01 micron coalescing filter ahead of it. The beds shed fine dust as the towers cycle, which is why a 1 micron particulate filter follows to protect valves and instruments downstream. Membrane fibers are just as sensitive to oil, and the membrane warranty goes from one year to three when the prefilter package is installed.

Desiccant after refrigerated, not instead of it

A refrigerated dryer ahead of a desiccant unit removes most of the water before it reaches the beds. The desiccant dryer then handles only the flow that needs a low dew point: on a 50 SCFM branch the purge is about 8 SCFM, where a plant-wide 400 SCFM heatless unit would vent about 60 SCFM around the clock.

Before you specify a lower dew point

Because every step below the dew point the pipe actually needs costs purge air and narrows the choice of dryer. A heatless twin tower reaches class 1 only on its 4-minute cycle, which switches towers two and a half times as often as the 10-minute class 2 setting, and a modular point-of-use unit reaches it only with inlet air held to 86°F. Neither the heated purge nor the blower purge design offers class 1 at all. Write down the class that the coldest pipe or the process limit demands; the ISO class guide shows how each one is read.

Out of the exhaust as vapor, not down a drain. A twin tower vents the water it collected through its purge muffler or, on a blower purge unit, through the blower exhaust; a membrane carries it off in the sweep; a single tower simply holds it in the gel untill the charge is changed. The only liquid drain in the system belongs to the coalescing prefilter ahead of the dryer. The mistake to avoid is piping a purge exhaust into a closed drain header: the back pressure slows regeneration, and the outlet dew point creeps up for no obvious reason.

It depends on the type: heatless twin towers accept 140°F, heated purge and blower purge units 40 to 120°F, membranes 150°F and single tower gel units 125°F. Those are ceilings, not design points. Ratings are stated at 100°F inlet, and hotter air carries more water into the bed, so the dryer either needs a bigger frame or gives up dew point. Class 1 from a modular heatless unit asks for 86°F or cooler. A refrigerated dryer upstream helps twice here: it takes out most of the water and it hands the desiccant stage air that is cooler than what left the compressor.

Floor strength, headroom, somewhere to vent and, depending on the type, an electrical feed. Twin towers run from 365 lb on the smallest heatless frame to 12,350 lb on the largest blower purge unit, and the tallest stand over 120 in before allowing room above to pour in desiccant. Heatless units need power for their controls only; heated and blower purge units need a feeder sized for heaters of up to 40 and 70 kW, and a room held between 40 and 120°F. Every type needs its purge or blower exhaust aimed where the noise and the moist air do no harm.

Because adsorbing water vapor releases heat, about as much as the same water would give up condensing, and the drying bed passes that heat to the air flowing through it. Behind a refrigerated dryer the rise is small, since little vapor is left to adsorb; on saturated air it is several times larger. The warmth does no harm to the dew point, and it is useful, because the heat front climbing the bed is what a demand purge control reads to judge when a tower is loaded. A dryer on saturated air whose outlet runs no warmer than its inlet deserves a look; the bed may be spent, or the air may be getting past it.