The HHX Series is the demand-purge version. A purge control that senses bed temperature matches purge to the moisture load the bed is actually seeing, so a lightly loaded dryer stops blowing away air it does not need to. It runs on 100 to 240 V single phase or 12 to 24 VDC, offers 4, 10 and 16 minute cycles for class 1, 2 and 3, keeps a 30-day data log and reports over Modbus TCP/IP and RS-485.
The HHE Series runs a fixed 10-minute cycle from a simple LED panel on 100 to 120 V single phase, and it is built for one target: minus 40°F. It purges the same amount whether the plant is at full load or idling over a weekend. Behind a compressor that runs flat out on two shifts that costs almost nothing extra, and the lower purchase price wins.
Both lines share frame dimensions and weights, from the 365 lb, 46 in tall 40 SCFM unit with 1 in NPT ports to the 5,400 SCFM frame on 6 in ANSI flanges. A later change from one control style to the other is a like-for-like fit on the same pad and piping.
Each dryer holds two towers of activated alumina. One dries the air while the other is depressurized and swept by a slice of the dried air, then the valves swap. Nothing is heated, so the only running cost beyond the controls is that sweep, called purge. Air flows up through the drying bed past stainless flow diffusers for a 4.8 second bed contact time, and separate fill and drain ports make the desiccant change a clean job.
Flows are rated at 100 psig, 100°F saturated inlet and 100°F ambient. At other pressures multiply by the published correction factor, which runs from 0.65 at 60 psig to 1.52 at 250 psig, before you pick a frame.
| MODEL | SERIES | SCFM | CONNECTION | H X W X D (IN) | WEIGHT (LB) |
| HHX-40 | HHX Series | 40 | 1 in NPT | 46 x 32 x 32 | 365 |
| HHX-60 | HHX Series | 60 | 1 in NPT | 61 x 32 x 32 | 445 |
| HHX-90 | HHX Series | 90 | 1 in NPT | 78 x 32 x 32 | 575 |
| HHX-115 | HHX Series | 115 | 1 in NPT | 54 x 44 x 38 | 685 |
| HHX-165 | HHX Series | 165 | 1 in NPT | 54 x 44 x 38 | 685 |
| HHX-260 | HHX Series | 260 | 2 in NPT | 72 x 49 x 38 | 1,010 |
| HHX-370 | HHX Series | 370 | 2 in NPT | 63 x 55 x 38 | 1,215 |
| HHX-450 | HHX Series | 450 | 2 in NPT | 71 x 55 x 38 | 1,350 |
| HHX-590 | HHX Series | 590 | 2 in NPT | 101 x 50 x 53 | 1,473 |
| HHX-750 | HHX Series | 750 | 3 in ANSI flange | 109 x 51 x 48 | 2,134 |
| HHX-930 | HHX Series | 930 | 3 in ANSI flange | 113 x 56 x 56 | 2,414 |
| HHX-1130 | HHX Series | 1,130 | 3 in ANSI flange | 113 x 59 x 56 | 2,875 |
| HHX-1350 | HHX Series | 1,350 | 3 in ANSI flange | 118 x 60 x 56 | 3,722 |
| HHX-1550 | HHX Series | 1,550 | 3 in ANSI flange | 113 x 66 x 56 | 4,167 |
| HHX-2100 | HHX Series | 2,100 | 4 in ANSI flange | 116 x 73 x 56 | 4,417 |
| HHX-3000 | HHX Series | 3,000 | 4 in ANSI flange | 122 x 78 x 65 | 9,010 |
| HHX-4100 | HHX Series | 4,100 | 6 in ANSI flange | 124 x 93 x 88 | 9,900 |
| HHX-5400 | HHX Series | 5,400 | 6 in ANSI flange | 126 x 102 x 92 | 12,000 |
| HHE-40 | HHE Series | 40 | 1 in NPT | 46 x 32 x 32 | 365 |
| HHE-60 | HHE Series | 60 | 1 in NPT | 61 x 32 x 32 | 445 |
| HHE-90 | HHE Series | 90 | 1 in NPT | 78 x 32 x 32 | 575 |
| HHE-115 | HHE Series | 115 | 1 in NPT | 54 x 44 x 38 | 685 |
| HHE-165 | HHE Series | 165 | 1 in NPT | 54 x 44 x 38 | 685 |
| HHE-260 | HHE Series | 260 | 2 in NPT | 72 x 49 x 38 | 1,010 |
| HHE-370 | HHE Series | 370 | 2 in NPT | 63 x 55 x 38 | 1,215 |
| HHE-450 | HHE Series | 450 | 2 in NPT | 71 x 55 x 38 | 1,350 |
| HHE-590 | HHE Series | 590 | 2 in NPT | 101 x 50 x 53 | 1,473 |
| HHE-750 | HHE Series | 750 | 3 in ANSI flange | 109 x 51 x 48 | 2,134 |
| HHE-930 | HHE Series | 930 | 3 in ANSI flange | 113 x 56 x 56 | 2,414 |
| HHE-1130 | HHE Series | 1,130 | 3 in ANSI flange | 113 x 59 x 56 | 2,875 |
| HHE-1350 | HHE Series | 1,350 | 3 in ANSI flange | 118 x 60 x 56 | 3,722 |
| HHE-1550 | HHE Series | 1,550 | 3 in ANSI flange | 113 x 66 x 56 | 4,167 |
| HHE-2100 | HHE Series | 2,100 | 4 in ANSI flange | 116 x 73 x 56 | 4,417 |
| HHE-3000 | HHE Series | 3,000 | 4 in ANSI flange | 122 x 78 x 65 | 9,010 |
| HHE-4100 | HHE Series | 4,100 | 6 in ANSI flange | 124 x 93 x 88 | 9,900 |
| HHE-5400 | HHE Series | 5,400 | 6 in ANSI flange | 126 x 102 x 92 | 12,000 |
A heatless dryer regenerates with its own product. A typical unit at full load blows roughly 15 percent of rated flow to atmosphere, about 75 SCFM on a 500 SCFM dryer, and every cubic foot of it was paid for at the compressor. Demand purge cuts that loss in proportion to how far below its rating the plant actually runs; on a fixed timer it stays constant. Check that the compressor has the margin before the dryer goes in.
Start from compressor delivery, not the plant average, then correct for the lowest pressure the dryer will see and the hottest inlet air. Inlet above 140°F is outside the rating and needs an aftercooler first. Behind a refrigerated dryer the inlet is cooler and far drier, the beds load slowly, and a demand control earns its keep. The sizing guide walks through the corrections.
Oil aerosol coats activated alumina and does not come off in regeneration, so a bed fouled once stays fouled. A coalescer goes ahead of the dryer and a particulate afterfilter behind it to catch the dust the beds shed as they cycle. Both lines can ship with a base package, a coalescing prefilter and particulate afterfilter, or an advanced package that adds a particulate stage ahead of the coalescer. See filter placement.
The 250 psig build, BSP or DIN flanges, premium butterfly switching valves on the two largest frames, mounting for a dew point monitor, stainless instrument tubing, low-ambient protection for unheated rooms and a NEMA 4 enclosure. Extended coverage to 5 years is available when the annual service kits are fitted on schedule.
Because regeneration depends on the pressure swing, and below about 60 psig the swing is too small to strip the off-line bed properly. Purge air expanded from line pressure to atmosphere becomes very dry and carries water out of the alumina; the lower the line pressure, the less that expansion achieves. Low pressure also means each SCFM takes up more volume, so velocity through the drying bed goes up and contact time falls. That is why the published correction factor drops to 0.65 at 60 psig, and why the 250 psig build carries a higher minimum of 120 psig.
Not on a fixed-cycle dryer: its purge is set to regenerate a bed loaded at full rated flow, and throttling the purge valve leaves water behind every cycle. The outlet does not fail at once. It drifts up over days as each tower starts its drying period a little wetter than the last, so the cause is rarely traced back to whoever turned the valve. The legitimate ways to purge less are a demand control that waits for the bed to load, or the 16-minute class 3 setting where minus 4°F is dry enough.
Through a muffler sized for the blowdown, or piped outdoors in a line larger than the exhaust port so it adds no back pressure. Each changeover dumps a tower full of compressed air in seconds, and in a small room the bang is enough to startle anyone working beside the dryer. Mufflers load with desiccant dust over the years, and a restricted one holds the regenerating tower above atmospheric pressure, which quietly spoils regeneration. Look at the muffler whenever the afterfilter element is changed and replace it when it no longer passes air freely.
Bring the header up to pressure slowly, with the dryer outlet valve cracked rather than wide open. A dryer that opens onto an empty header passes air at low pressure and high velocity, which lifts the alumina, wears it into dust and sends a slug of wet air downstream. Once the line is at pressure, open the outlet fully and let the dryer complete a few cycles before trusting the dew point. Where the plant regularly starts from zero, a minimum-pressure valve after the dryer does the same job automatically and spares the bed every Monday morning.
The dew point slips first, then the desiccant suffers. The frames are built around a 4.8 second bed contact time at rated flow; push more air through and the water front reaches the top of the bed before the tower switches, so wet air leaves near the end of each drying period. Sustained overflow also lifts velocity enough to fluidize the beads, wearing them into dust that loads the afterfilter. The usual cause is a compressor added or upsized after the dryer was bought, with nobody checking the dryer. A dew point that goes bad only during the busiest hour of the shift is the classic signature.
When every pipe in the system stays well above minus 4°F and no specification names a lower class. That fits outdoor headers and unheated buildings in climates where winter lows stay comfortably above that, where the only goal is keeping water from freezing in the pipe. On the demand line class 3 runs a 16-minute cycle, so each tower stays on line longer and the dryer blows down less often than on the 10-minute class 2 cycle, and every blowdown avoided is air kept. Before choosing it, walk the system for the pipe nobody remembered, such as a line over a dock door.