HPRN Series Non-Cycling Refrigerated Air Dryers

PRODUCTTYPEFLOWRATING
Refrigerated Air DryerNon-Cycling, previous generation75 to 1,200 SCFM232 psig / 120°F inlet

Specifications


Configuration & Size

Sizes:
75, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1,000, 1,200 SCFM
Power:
115/1/60 to 150 SCFM, 460/3/60 from 200 SCFM; 0.52 to 8.7 kW
Connections:
1 in and 2 in NPT to 600 SCFM, 3 in and 4 in flanges above
Replaced by:
DXR Series, matched on corrected flow

Features

  • Stainless steel cross-flow plate heat exchangers with a stamped herringbone geometry for turbulent flow and slow fouling
  • Integral demister separator feeding a timed electric drain, with a Y-strainer ahead of the solenoid
  • Dew point display on the 75 to 150 SCFM units; LED display plus a dry-air alarm contact from 200 SCFM up
  • Two-year warranty as standard, five years when bought with the filter package and serviced with annual kits

Ratings

  • Max inlet pressure: 232 psig (43 psig minimum)
  • Max inlet temperature: 120°F
  • Ambient range: 37 to 110°F (34°F minimum from 600 SCFM up)
  • Pressure dew point: 38°F, ISO 8573-1 class 4-5
  • Refrigerant: R-134a to 125 SCFM, R-407C from 150 SCFM

Plate exchangers and a demister in one cabinet

The construction that made the HPRN a plant-air workhorse

The HPRN Series carried the mid-range non-cycling duty from 75 to 1,200 SCFM on thirteen sizes: stainless steel plate heat exchangers with a stamped herringbone pattern that keeps the air turbulent, an integral demister ahead of a timed electric drain, 115 V single phase through 150 SCFM and 460 V three phase from 200 SCFM up. It is the previous generation and is no longer built. Replacements in this flow range are quoted from the DXR Series, the current non-cycling line, size for size on the corrected flow. The HPRN part numbers remain here so a nameplate can be matched to its current equivalent in one step.

Where the DXR Series picks up. DXR sizes from 85 to 1,250 SCFM overlap the HPRN range with a model at or just above every old rating; Single-phase 115 V through 150 SCFM on both lines, so the small replacements need no new circuit; Hot-gas bypass control and a 38°F dew point on both, with R513A or R410A in place of R-134a and R-407C; A zero-loss drain is standard on the DXR, replacing the timed drain that vented air on every cycle.

Cross-referencing an HPRN. Start from the number in the model: an HPRN400-4 was a 400 SCFM, 460 V unit at standard conditions; Apply the inlet, ambient and pressure factors to today's duty; a plant at 80 psig with 110°F inlet air needs about 35 percent more nameplate; Pick the DXR model at or above the corrected figure and check that its connection size suits the existing pipe.



HPRN Series refrigerated air dryer close-up

Nameplate flow, then the corrections, then the DXR size

Request a Quote

HPRN Series Part Numbers

Part Number SCFM Connection Voltage Power Dimensions (in) Weight (lb)
HPRN75 75 1 in NPT 115/1/60 0.52 kW 24 x 14 x 32 123
HPRN100 100 1 in NPT 115/1/60 0.65 kW 24 x 14 x 32 129
HPRN125 125 1 in NPT 115/1/60 0.68 kW 24 x 14 x 32 135
HPRN150-1 150 1 in NPT 115/1/60 0.91 kW 24 x 14 x 35 148
HPRN200-4 200 1 in NPT 460/3/60 1.81 kW 30 x 17 x 36 165
HPRN250-4 250 2 in NPT 460/3/60 1.92 kW 30 x 17 x 36 205
HPRN300-4 300 2 in NPT 460/3/60 2.48 kW 30 x 20 x 38 212
HPRN400-4 400 2 in NPT 460/3/60 3.09 kW 30 x 21 x 38 225
HPRN500-4 500 2 in NPT 460/3/60 3.18 kW 32 x 21 x 48 328
HPRN600 600 2 in NPT 460/3/60 3.8 kW 32 x 22 x 50 353
HPRN800 800 3 in flange 460/3/60 5.4 kW 59 x 30 x 42 687
HPRN1000 1,000 4 in flange 460/3/60 6.6 kW 64 x 29 x 45 786
HPRN1200 1,200 4 in flange 460/3/60 8.7 kW 64 x 29 x 45 810

Flows are at 100 psig and 100°F inlet in a 100°F room, and the -1 and -4 suffixes mark 115 V single-phase and 460 V three-phase builds. These part numbers are the previous generation and are kept for cross-reference; new orders in this range are supplied from the DXR Series, the current non-cycling line.

HPRN Series Applications


HPRN Series dimensional outline drawing

Cabinet sizes, connections and clearances

From a 123 lb floor unit to an 810 lb dryer on 4 in flanges.

The 75, 100 and 125 SCFM units share a 24 x 14 x 32 in cabinet at 123 to 135 lb with 1 in NPT connections; the 150 SCFM unit is 3 in deeper. The 200 and 250 SCFM cabinets are 30 x 17 x 36 in, the 300 and 400 grow to 30 x 20 x 38 and 30 x 21 x 38 in, and the 500 and 600 to 32 x 21 x 48 and 32 x 22 x 50 in at 328 and 353 lb. Connections are 1 in NPT through 200 SCFM and 2 in NPT from 250 to 600 SCFM.

Above that the cabinet changes: the 800 SCFM unit is 59 x 30 x 42 in at 687 lb with a 3 in flange, and the 1,000 and 1,200 SCFM units are 64 x 29 x 45 in at 786 and 810 lb with 4 in flanges. All sizes are air-cooled and want free air to the condenser face and room to pull the panels for coil cleaning, with the hot-air discharge pointed away from the compressor intake. When a DXR replaces one of these, compare the connection size and the height of the inlet and outlet before the crew arrives, because the new cabinets are laid out differently.

The drawing above is the original HPRN cabinet; outline drawings for the replacement DXR size are supplied with every quote.

Common FAQs

75 to 1,200 SCFM

  • Sizes: 75, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1,000, 1,200 SCFM
  • Power: 115/1/60 to 150 SCFM, 460/3/60 from 200 SCFM; 0.52 to 8.7 kW
  • Connections: 1 in and 2 in NPT to 600 SCFM, 3 in and 4 in flanges above
  • Replaced by: DXR Series, matched on corrected flow
  • Max inlet pressure: 232 psig (43 psig minimum)
  • Max inlet temperature: 120°F
  • Ambient range: 37 to 110°F (34°F minimum from 600 SCFM up)
  • Pressure dew point: 38°F, ISO 8573-1 class 4-5
  • Refrigerant: R-134a to 125 SCFM, R-407C from 150 SCFM