Above 725 psig the compressed air world changes: multi-stage piston compressors, storage banks of steel cylinders, 1/2 in tube and fittings rated in thousands of psi, and flows measured in tens of SCFM rather than hundreds. Breathing-air fill stations, hydrostatic and pneumatic test stands, gas-charging benches and high-pressure storage all need the water out before it reaches a cylinder or a valve seat, and this series is the refrigerated dryer built for that pressure.
The series is a matrix: four pressure classes of 1,200, 3,625, 5,000 and 6,000 psig, each in eight flow sizes of 20, 30, 40, 60, 100, 125, 200 and 275 SCFM, giving 32 models. Every one carries a stainless steel tube-in-tube heat exchanger with all-stainless air-side components, 1/2 in NPT connections, and a hermetic refrigeration circuit delivering a 38°F pressure dew point at rated flow.
Sizes to 100 SCFM run on 115 V single phase, 125 SCFM on 230 V, and 200 and 275 SCFM on 460 V three phase, absorbing 0.3 to 2.5 kW. A general arrangement drawing exists for every model, which matters when the dryer must fit a fill-station skid or a test-cell wall.
Flow is rated at 100 psig reference conditions and 100°F inlet; the last figure in the part number is the pressure class in psig. Every model links to its own specification page.
| PART NUMBER | SERIES | SCFM | CONNECTION | VOLTAGE | STATUS |
| AXHP-20-1200 | AXHP Series | 20 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-20-3625 | AXHP Series | 20 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-20-5000 | AXHP Series | 20 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-20-6000 | AXHP Series | 20 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-30-1200 | AXHP Series | 30 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-30-3625 | AXHP Series | 30 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-30-5000 | AXHP Series | 30 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-30-6000 | AXHP Series | 30 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-40-1200 | AXHP Series | 40 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-40-3625 | AXHP Series | 40 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-40-5000 | AXHP Series | 40 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-40-6000 | AXHP Series | 40 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-60-1200 | AXHP Series | 60 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-60-3625 | AXHP Series | 60 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-60-5000 | AXHP Series | 60 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-60-6000 | AXHP Series | 60 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-100-1200 | AXHP Series | 100 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-100-3625 | AXHP Series | 100 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-100-5000 | AXHP Series | 100 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-100-6000 | AXHP Series | 100 | 1/2 in NPT | 115/1/60 | Current |
| AXHP-125-1200 | AXHP Series | 125 | 1/2 in NPT | 230/1/60 | Current |
| AXHP-125-3625 | AXHP Series | 125 | 1/2 in NPT | 230/1/60 | Current |
| AXHP-125-5000 | AXHP Series | 125 | 1/2 in NPT | 230/1/60 | Current |
| AXHP-125-6000 | AXHP Series | 125 | 1/2 in NPT | 230/1/60 | Current |
| AXHP-200-1200 | AXHP Series | 200 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-200-3625 | AXHP Series | 200 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-200-5000 | AXHP Series | 200 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-200-6000 | AXHP Series | 200 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-275-1200 | AXHP Series | 275 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-275-3625 | AXHP Series | 275 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-275-5000 | AXHP Series | 275 | 1/2 in NPT | 460/3/60 | Current |
| AXHP-275-6000 | AXHP Series | 275 | 1/2 in NPT | 460/3/60 | Current |
Select the class above the system's maximum working pressure, not its normal pressure. A breathing-air station filling 4,500 psig cylinders runs its compressor to 5,000 psig or more and takes the 5,000 or 6,000 class; a 3,000 psig storage bank takes the 3,625 class; a 1,000 psig test loop takes the 1,200 class. Within the class, pick the flow size at or above the compressor's delivery: a 15 hp four-stage compressor makes 25 to 35 SCFM, so it takes the 40 SCFM model, and a 40 hp machine at 100 SCFM takes the 100 or 125. The higher classes cost more for the same flow because the exchanger tubing is thicker, so do not buy 6,000 psig for a 1,200 psig system.
At 5,000 psig a flow of 100 SCFM is less than 0.3 actual cubic feet per minute, so the exchanger is a coil of small-bore stainless tube rather than a plate block, and the whole dryer weighs less than a plant-air dryer of a tenth the pressure. The water content of the air is small too, because most of it condensed in the compressor's interstage coolers, but what remains will freeze in a 4,500 psig regulator or corrode a cylinder valve if it is not removed.
Pipe the dryer after the final-stage aftercooler and separator with the same tube, fittings and pressure rating as the rest of the system, and fit the drain with a high-pressure timed drain rated for the class; the drains page lists 600 to 6,000 psig versions in brass and stainless. Put a high-pressure particulate and coalescing filter after the dryer, and keep the dryer's own 40 to 120°F ambient range in mind in a fill-station room that shares its heat with the compressor. Give the condenser clear air on both faces.
At 38°F pressure dew point the air is dry enough for storage, test and charging duty and for the first stage of a breathing-air purifier train. It is not, on its own, breathing air: a fill station still needs its purification cartridges for oil vapor, carbon monoxide and the final dew point, and those cartridges last far longer when a refrigerated dryer has already taken the bulk water out ahead of them. Systems that need a dew point below freezing at pressure move to desiccant; the refrigerated versus desiccant page draws the line.
Start from the general arrangement drawing for the exact model, because skid space is usualy the constraint. The dryer goes after the final-stage aftercooler and separator, ahead of the purification cartridges, with both condenser faces open to moving air. Fill rooms are often heated by the compressor itself, so check that the dryer sits within its 40 to 120°F ambient range on the hottest filling day.
The exchanger tubing wall has to be thicker for the higher class, and the fittings and test pressures rise with it, while the refrigeration circuit is the same size for the same SCFM. So buying 6,000 psig for a 1,000 psig test loop pays for steel the system will never use. The exception is a plant that knows it will raise the system pressure soon, where buying the class once is cheaper than buying the dryer twice.
A high-pressure timed solenoid drain rated at or above the 3,625 psig class, in brass or stainless. Rate it to the system's relief setting, because that is the pressure it will see when something upstream misbehaves. The discharge leaves at full pressure, so pipe it to a collection vessel or separator rather than an open floor drain, where the blast scatters condensate and oil across the room.
Not within its rating. The series is specified for 40 to 120°F ambient, and a refrigerated dryer in a cold room loses control of its circuit while the condensate in its drain and lines starts to freeze. A frozen drain at 5,000 psig means water passing on to the cylinders. Heat the room or the enclosure, or move the dryer to the warm side of the wall with the compressor.