The PHDM Series runs from a 3 SCFM unit 16.7 in tall and 9.4 in wide, light enough to carry at 21.8 lb, to a 177 SCFM unit on 1-1/2 in NPT. The 3, 9 and 15 SCFM sizes share the narrow 9.4 in body; 24 through 88 SCFM use an 18.7 in body; 118 through 177 SCFM step up to 21.1 in. Height grows with flow inside each group.
It replaces the earlier HSHD wall-mount modular dryer, which covered 7 to 40 SCFM. Anyone looking for an HSHD replacement can pick the size of the same or next larger flow and gain the standard filter package and a wider range. An energy management controller is offered on the 24 to 177 SCFM sizes to cut purge at partial load, along with several connection options.
A modular heatless dryer works on the same pressure-swing principle as a twin-tower unit, but the beds sit in aluminum columns sized for a single machine or a short branch. That keeps it compact enough for a lab, a machine frame or a cramped mezzanine, and lets a plant already dried by a refrigerated dryer add minus 40°F only where it is needed.
Flows are rated at 100 psig on the standard 8-minute, minus 40°F cycle. Pick the size from the flow the machine actually draws, then apply the pressure correction for the line it hangs on.
| MODEL | SERIES | SCFM | CONNECTION | H X W X D (IN) | WEIGHT (LB) |
| PHDM 3 | PHDM Series | 3 | 3/8 in NPT | 16.7 x 9.4 x 8.3 | 21.8 |
| PHDM 9 | PHDM Series | 9 | 3/8 in NPT | 32.4 x 9.4 x 8.3 | 35 |
| PHDM 15 | PHDM Series | 15 | 3/8 in NPT | 42.2 x 9.4 x 8.3 | 46 |
| PHDM 24 | PHDM Series | 24 | 1/2 in NPT | 38.1 x 18.7 x 14.3 | 101.5 |
| PHDM 32 | PHDM Series | 32 | 3/4 in NPT | 44 x 18.7 x 14.3 | 121.2 |
| PHDM 41 | PHDM Series | 41 | 3/4 in NPT | 51.9 x 18.7 x 14.3 | 136.7 |
| PHDM 59 | PHDM Series | 59 | 1 in NPT | 65.9 x 18.7 x 14.3 | 180.8 |
| PHDM 88 | PHDM Series | 88 | 1 in NPT | 73.7 x 18.7 x 14.3 | 186.5 |
| PHDM 118 | PHDM Series | 118 | 1-1/2 in NPT | 67.1 x 21.1 x 19.5 | 352.7 |
| PHDM 147 | PHDM Series | 147 | 1-1/2 in NPT | 75 x 21.1 x 19.5 | 396.8 |
| PHDM 177 | PHDM Series | 177 | 1-1/2 in NPT | 75 x 21.1 x 19.5 | 396.8 |
Point-of-use dryers often sit on branches well below header pressure, after a regulator or a long run. The published correction factors span 0.31 to 1.44 across 50 to 150 psig, so in the worst case a dryer on a low-pressure branch loses more than half its rated flow. Size from the pressure at the dryer inlet, and put the dryer upstream of the regulator rather than after it.
Minus 94°F is reached on the 4-minute cycle only with inlet air at 86°F or cooler. Air straight from a compressor aftercooler in summer is usually hotter than that. Put the dryer downstream of a refrigerated dryer or a well-sized aftercooler, and keep it out of the heat of the compressor room.
A refrigerated dryer on the main header removes the bulk of the water at 38°F, and this dryer then takes one branch down to minus 40°F. Its beds load far more slowly than they would on saturated air, and its purge is a small fraction of what a plant-wide desiccant dryer would vent. The reasoning is laid out on refrigerated vs desiccant.
Electronics and lab benches, laser cutting assist gas, injection molding resin conveying, analyzer and instrument air, and the one line that leaves the building. If the need is a machine rather than a building, start here.
On a machine that idles for long stretches, usually yes; on one that draws steady air all shift, rarely. A timed heatless dryer purges on its cycle whether the machine is cutting or waiting, so the air it spends during idle hours is pure loss. The controller, offered from the 24 SCFM size upward, trims purge to the load actually arriving. A laser that sits between jobs or a lab bench used in bursts repays it quickly. The three smallest sizes do not take it, and their purge is small in absolute terms anyway.
Above 177 SCFM, the top of the modular range, or when several branches each need minus 40°F and one central dryer could serve them all. In the overlap between 40 and 177 SCFM, compare floor space and weight: a 59 SCFM modular unit stands on an 18.7 x 14.3 in base at 180.8 lb, while the smallest heatless twin towers need a 32 x 32 in base and weigh 365 to 575 lb. The modular unit wins beside a machine; the twin tower wins on a header, where its controls and data logging pay back accross many users.
It suddenly sees several times the water vapor, about eight times on saturated 100°F air, plus any liquid the failed dryer no longer separates, and whether the dew point holds depends on the margin left. The flow ratings already assume saturated inlet air, so a unit running well inside its rating on a cool branch can ride out a short outage. One sized tight, fed warm air or set for class 1 at its 86°F limit will lose its dew point quickly. Liquid is the real danger: keep the prefilter drain working so slugs never reach the columns, and treat the refrigerated dryer alarm as an alarm for the whole branch.
Upstream of all three, and well upstream of any lubricator. A lubricator puts an oil mist into the air on purpose, and that mist ends a desiccant bed exactly as compressor oil does; it is a common way a modular unit with good filters still gets fouled. Leave the machine's own filter in place after the dryer, where it catches any scale between the dryer and the tool.
It vents a short blowdown each time the columns switch, every 4 minutes on the class 2 cycle and every 2 minutes on class 1, and it can work in a lab if that exhaust is handled. The purge between switches is a soft hiss; the switch itself is the sharp sound. Fit an exhaust muffler, point it away from benches and people, or pipe the exhaust to a service corridor in a line generous enough to add no back pressure. In a quiet instrument room, the simplest fix is to mount the dryer outside and run the dried line in.