HITN Series High Inlet Temperature Air Dryers

PRODUCTTYPEFLOWRATING
Refrigerated Air DryerHigh Inlet Temperature, previous generation20 to 125 SCFM227 psig / 180°F inlet

Specifications


Configuration & Size

Sizes:
20, 25, 35, 50, 75, 125 SCFM
Power:
115/1/60 to 75 SCFM, 230/1/60 at 125 SCFM; 0.69 to 1.97 kW
Connections:
3/4 in NPT to 35 SCFM, 1 in NPT from 50
Replaced by:
HRHT Series, size for size

Features

  • Two-stage separator and filter ahead of the chiller take out the bulk water that hot discharge air carries
  • Stainless steel brazed-plate exchangers on a hermetic refrigeration circuit, sized for the extra heat load of 180°F inlet
  • Adjustable timed electric drain plus an air-operated drain, so both separation stages empty
  • Lighted on/off switch, dew point indicator and a fault light on the front panel

Ratings

  • Rated conditions: 180°F inlet, 125 psig, 100°F ambient
  • Max inlet pressure: 227 psig (42 psig minimum)
  • Max ambient: 110°F
  • Pressure dew point: 50°F, ISO 8573-1 class 6
  • Refrigerant: R-134a to 25 SCFM, R-407C from 35 SCFM

Built for 180°F air off a piston compressor

Separation before cooling, then a refrigeration circuit sized for the heat

The HITN Series was the dryer for a small piston compressor with no aftercooler, rated to take 180°F air straight off the discharge: six sizes from 20 to 125 SCFM with a hermetic refrigeration circuit, stainless steel brazed-plate exchangers and a two-stage separator ahead of the chiller to knock the water out of hot, wet air before it is cooled. All but the largest run on 115 V. It is the previous generation. New orders are filled from the HRHT Series, rated for 200°F inlet, size for size, and the HITN part numbers stay listed here so an old unit can be matched to its replacement.

The replacement: HRHT at 200°F. Every HITN size to 75 SCFM maps to an HRHT of the same or next rating: HITN25 to HRHT25A, HITN50 to HRHT60A, HITN75 to HRHT80A; The 200°F inlet rating of the HRHT covers a compressor that runs hotter than the HITN was designed for; All five HRHT sizes are 115 V; the 230 V HITN125 is matched on corrected flow to the HRHT100A or to the 125 SCFM size of the HTR Series; R513A refrigerant in place of R-134a and R-407C, with a zero-loss drain in place of the timed drain.

Matching a HITN nameplate. The model number is the flow at 180°F inlet: a HITN35 handled a 10 hp piston compressor at 35 SCFM; If the compressor discharge now runs above 180°F, the 200°F rating of the HRHT is a reason to change rather than simply replace; A high-temperature prefilter rated for hot air belongs ahead of either dryer when the compressor has no aftercooler.



HITN Series refrigerated air dryer close-up

Flow first, then the compressor temperature

Request a Quote

HITN Series Part Numbers

Part Number SCFM Connection Voltage Power Dimensions (in) Weight (lb)
HITN20 20 3/4 in NPT 115/1/60 0.69 kW 29 x 14 x 17 100
HITN25 25 3/4 in NPT 115/1/60 0.69 kW 29 x 14 x 17 100
HITN35 35 3/4 in NPT 115/1/60 0.99 kW 29 x 14 x 17 106
HITN50 50 1 in NPT 115/1/60 0.83 kW 41 x 18 x 17 125
HITN75 75 1 in NPT 115/1/60 1.13 kW 41 x 18 x 17 130
HITN125 125 1 in NPT 230/1/60 1.97 kW 46 x 18 x 17 153

Flows are at the high-temperature rating point of 180°F inlet, 125 psig and 100°F ambient rather than the 100°F standard used for other dryers, so a 50 SCFM HITN handled a 50 SCFM piston compressor with no derating. These part numbers are the previous generation; new orders are supplied from the HRHT Series, which is the direct replacement.

HITN Series Applications


HITN Series dimensional outline drawing

Three cabinets, top-mounted fan, pre-drilled base rail

Sized to stand beside a small piston compressor.

The HITN20, HITN25 and HITN35 share a 29 x 14 x 17 in cabinet at 100 to 106 lb with 3/4 in NPT connections. The HITN50 and HITN75 are 41 x 18 x 17 in at 125 and 130 lb, and the HITN125 is 46 x 18 x 17 in at 153 lb; those three carry 1 in NPT. The condenser fan is on top, so the cabinet needs headroom rather than side clearance, and the base rail is pre-drilled for anchoring to the floor next to the compressor.

The HRHT replacements are close in size: the HRHT35A is 29.7 x 14.6 x 16.9 in at 117 lb and the 60 to 100 SCFM units are 30.0 x 16.6 x 22.4 in at 123 to 132 lb, all on 3/4 in or 1 in NPT. Because the air arrives hot, keep the run from the compressor to the dryer short and fit a high-temperature prefilter on it; pipe both drains to a condensate separator, and keep the room under 110°F.

The outline above is the HITN cabinet; the matching HRHT drawing is supplied with every replacement quote.

Common FAQs

20 to 125 SCFM

  • Sizes: 20, 25, 35, 50, 75, 125 SCFM
  • Power: 115/1/60 to 75 SCFM, 230/1/60 at 125 SCFM; 0.69 to 1.97 kW
  • Connections: 3/4 in NPT to 35 SCFM, 1 in NPT from 50
  • Replaced by: HRHT Series, size for size
  • Rated conditions: 180°F inlet, 125 psig, 100°F ambient
  • Max inlet pressure: 227 psig (42 psig minimum)
  • Max ambient: 110°F
  • Pressure dew point: 50°F, ISO 8573-1 class 6
  • Refrigerant: R-134a to 25 SCFM, R-407C from 35 SCFM

The HITN Series is the previous generation. New orders are supplied from the HRHT Series, its direct replacement; the part numbers below are listed for matching an installed unit.