1-805-484-2992

Quotes - Engineering - Sales
GFN Series Filters compressed air filter, three-quarter view

GFN Series Compressed Air Filters

PRODUCTGRADESFLOWRATING
Inline Coalescing FilterM1, M01, AC6 to 1,500 SCFM232 psig / 176°F

Specifications


Configuration & Size

Housings:
0006, 0015, 0025, 0032, 0050, 0070, 0085, 0105, 0125, 0175, 0280, 0325, 0450, 0700, 0850, 0900, 1250, 1500
Connections:
1/8 in NPT to 3 in NPT
Elements:
GE (size) (grade); several housings share one element size
Drains:
Float drain on M1 and M01, manual drain on AC

Features

  • M1: 1 micron particulate and coalescing, 0.3 ppm oil at 68°F, ISO class 3; the prefilter that keeps oil and rust off the dryer exchanger
  • M01: 0.01 micron high-efficiency coalescer, 0.01 ppm oil, ISO class 2; the afterfilter for tools, valves, paint and packaging
  • AC: activated carbon, 0.003 ppm, ISO class 1; goes downstream of an M01, never in front of one
  • Tested to ISO 12500 so the ppm figures are measured, not estimated

Ratings

  • Max pressure: 232 psig; minimum 22 psig on 0070 and up
  • Temperature: 32 to 176°F (M1, M01); 32 to 122°F (AC)
  • ISO 8573-1 oil: M1 class 3, M01 class 2, AC class 1
  • Element change: 12 months for M1 and M01; 1,000 hours for AC
  • Warranty: 10 years on the housing

Three grades that map onto the ISO 8573-1 oil classes

M1 before the dryer, M01 after it, AC where vapor matters

The GFN Series is the current general-purpose inline filter for the cycling, non-cycling and high-temperature dryers here. Eighteen die-cast aluminum housings run from 6 SCFM on 1/8 in NPT to 1,500 SCFM on 3 in NPT, and each is ordered with one of three grades: M1, a 1 micron coalescing prefilter that holds oil carryover to 0.3 ppm; M01, a 0.01 micron coalescer at 0.01 ppm; or AC, an activated-carbon adsorber that takes oil vapor down to 0.003 ppm. The dryer tables pair an M1 prefilter with an M01 afterfilter of the same housing for every cycling dryer size, so the filter set is settled with the dryer.

Housing built for a fast element change. Die-cast aluminum with an electrocoat inside and out and a powder coat outside; condensate and acidic oil do not pit the bowl; No tie rod through the element, so the bowl unscrews and the element drops free in one motion; Deep-pleated borosilicate microfiber media on glass-filled nylon end caps, sized for low pressure drop; Automatic float drain fitted on M1 and M01 housings; differential pressure gauge kit GFDP 0050 or GFDP 1500 adds the change indicator.

Matched to the dryer by size code. A 105 SCFM cycling dryer takes GFN 0105 M1 in and GFN 0105 M01 out on 1 in NPT; a 400 SCFM unit takes the 0450 pair on 2 in; The high-temperature dryers take an M1 inlet filter from GFN 0050 to GFN 0175 ahead of the 180°F inlet; Element sharing keeps stock simple: GFN 0070, 0085 and 0105 all use the GE 0105 element.



GFN Series Filters compressed air filter close-up

The same housing number in M1 ahead of the dryer and M01 behind it

Request a Quote

GFN Series Filters Part Numbers

Part Number SCFM Connection Grade Element
GFN 0006 M1 6 1/8 in NPT M1 GE 0015 M1
GFN 0015 M1 15 1/4 in NPT M1 GE 0015 M1
GFN 0025 M1 25 1/4 in NPT M1 GE 0032 M1
GFN 0032 M1 32 3/8 in NPT M1 GE 0032 M1
GFN 0050 M1 50 1/2 in NPT M1 GE 0050 M1
GFN 0070 M1 70 1/2 in NPT M1 GE 0105 M1
GFN 0085 M1 85 3/4 in NPT M1 GE 0105 M1
GFN 0105 M1 105 1 in NPT M1 GE 0105 M1
GFN 0125 M1 125 3/4 in NPT M1 GE 0175 M1
GFN 0175 M1 175 1 in NPT M1 GE 0175 M1
GFN 0280 M1 280 1-1/4 in NPT M1 GE 0325 M1
GFN 0325 M1 325 1-1/2 in NPT M1 GE 0325 M1
GFN 0450 M1 450 2 in NPT M1 GE 0450 M1
GFN 0700 M1 700 2 in NPT M1 GE 0700 M1
GFN 0850 M1 850 2-1/2 in NPT M1 GE 0900 M1
GFN 0900 M1 900 3 in NPT M1 GE 0900 M1
GFN 1250 M1 1,250 3 in NPT M1 GE 1250 M1
GFN 1500 M1 1,500 3 in NPT M1 GE 1500 M1

Flows are at 100 psig; each housing is also supplied as the M01 and AC grade under the same size code, with the matching GE element, and the note column shows the cycling dryer size each housing is paired with.

GFN Series Filters Applications


GFN Series Filters dimensional outline drawing

Dimensions and mounting

Ports in line through the head, bowl down, element out below.

The housing sits upright in the line with the inlet and outlet in the head and the bowl hanging below. The arrow on the head sets the flow direction; the coalescing element drains oil down its outside surface, and a housing installed backwards blows that oil straight into the dryer or the tools. Leave room under the bowl for the bowl length plus the element length so the element can be pulled without disturbing the pipe, and keep the housing within reach of a wrench: on the 0700 and larger sizes on 2 in to 3 in pipe the bowl is long enough that a housing tucked under a receiver cannot be serviced.

The float drain discharges from the bottom of the bowl; run a tube to a condensate line rather than letting it drip. The AC housing has a manual drain because a carbon element must run dry; anything wet reaching it is a sign the M01 ahead of it has failed. Fit the differential pressure gauge on the head where it can be read from the walkway.

Confirm the housing height, the port size and the drain kit with the quote; the drawing above is representative of the threaded housings.

Common FAQs

6 to 1,500 SCFM

  • Housings: 0006, 0015, 0025, 0032, 0050, 0070, 0085, 0105, 0125, 0175, 0280, 0325, 0450, 0700, 0850, 0900, 1250, 1500
  • Connections: 1/8 in NPT to 3 in NPT
  • Elements: GE (size) (grade); several housings share one element size
  • Drains: Float drain on M1 and M01, manual drain on AC
  • Max pressure: 232 psig; minimum 22 psig on 0070 and up
  • Temperature: 32 to 176°F (M1, M01); 32 to 122°F (AC)
  • ISO 8573-1 oil: M1 class 3, M01 class 2, AC class 1
  • Element change: 12 months for M1 and M01; 1,000 hours for AC
  • Warranty: 10 years on the housing

Quote Request Form:

Questions?

1-805-484-2992