DXR Series Non-Cycling Refrigerated Air Dryers

PRODUCTTYPEFLOWRATING
Refrigerated Air DryerNon-Cycling, direct expansion10 to 4,200 SCFM203 psig / 131°F inlet

Specifications


Configuration & Size

Sizes:
27 models, 10 to 4,200 SCFM
Power:
115/1/60 to 150 SCFM, 230/1/60 at 185 and 230, 460/3/60 from 250 SCFM (575 V optional from 850)
Connections:
1/2 in NPT to 6 in ANSI flange
Refrigerant:
R513A to 65 SCFM, R410A from 85 SCFM

Features

  • Incoming air is precooled by the outgoing dry air before it reaches the refrigerant section, which cuts refrigeration load and reheats the outlet
  • The separator sits at the coldest point of the block, where the condensate has already dropped out and is easiest to catch
  • Reheated outlet air leaves well above its dew point, so the downstream pipe does not sweat
  • Zero-loss condensate drain fitted as standard, so nothing but water leaves the separator

Ratings

  • Max inlet pressure: 203 psig (232 psig on the 10 to 30 SCFM units)
  • Max inlet temperature: 131°F; 140°F from 325 SCFM up
  • Max ambient: 115°F
  • Pressure dew point: 38°F, ISO 8573-1 class 4-5
  • Cooling: Air-cooled

One exchanger block does three jobs

Precooler, chiller and separator in a single core

The DXR Series is the widest single non-cycling range we sell: 27 direct-expansion dryers from 10 to 4,200 SCFM that share one design idea, an all-in-one exchanger that puts the air-to-air precooler, the air-to-refrigerant chiller and the water separator in a single block. A hot-gas bypass valve keeps the evaporator just above freezing whatever the load, so the 38°F dew point holds at 20 percent flow as well as at 100. A zero-loss drain and a digital dew point display are standard on every size. It is the lowest-first-cost choice for a plant that runs at a steady load, and the fine model steps mean the fit is exact rather than approximate.

Non-cycling control that holds the dew point. The refrigeration compressor runs continuously; a hot-gas bypass valve feeds discharge gas into the evaporator as load falls so it never ices; Dew point holds steady from full flow down to no flow, which is what an instrument line or a paint booth needs; Digital pressure dew point display on the panel shows at a glance whether the dryer is doing its job; Two refrigerants across the range: low-GWP R513A on the 10 to 65 SCFM units, R410A from 85 SCFM up.

Sized for the compressor, not the pipe. The steps run 10, 15, 20, 30, 50, 65, 85, 105, 125, 150, 185, 230, 250 SCFM and on up, so the next size above a corrected duty is rarely more than 20 percent larger; A 25 hp rotary screw at 110 SCFM lands on the DXR 0125 with margin; a 100 hp screw at 450 SCFM lands on the DXR 0500; Single-phase 115 V through 150 SCFM means the small units plug in beside the compressor.



DXR Series refrigerated air dryer close-up

Twenty-seven steps mean no size is a big jump

Request a Quote

DXR Series Part Numbers

Part Number SCFM Connection Voltage Power Dimensions (in) Weight (lb)
DXR 0010 NA 10 1/2 in MNPT 115/1/60 0.19 kW 18 x 14 x 20 42
DXR 0015 NA 15 1/2 in MNPT 115/1/60 0.18 kW 18 x 14 x 20 42
DXR 0020 NA 20 1/2 in MNPT 115/1/60 0.22 kW 20 x 14 x 18 45
DXR 0030 NA 30 1/2 in FNPT 115/1/60 0.33 kW 18 x 14 x 20 56
DXR 0050 NA 50 1/2 in FNPT 115/1/60 0.9 kW 31 x 15 x 21 113
DXR 0065 NA 65 3/4 in FNPT 115/1/60 0.9 kW 31 x 15 x 21 113
DXR 0085 NA 85 1 in FNPT 115/1/60 0.99 kW 32 x 19 x 23 119
DXR 0105 NA 105 1 in FNPT 115/1/60 0.99 kW 32 x 19 x 23 119
DXR 0125 NA 125 1 in FNPT 115/1/60 1.0 kW 32 x 19 x 23 135
DXR 0150 NA 150 1 in FNPT 115/1/60 1.5 kW 32 x 19 x 23 146
DXR 0185 NA 185 1-1/2 in FNPT 230/1/60 1.63 kW 36 x 23 x 24 170
DXR 0230 NA 230 1-1/2 in FNPT 230/1/60 1.95 kW 36 x 23 x 24 170
DXR 0250 NA 250 1-1/2 in FNPT 460/3/60 3.11 kW 36 x 23 x 24 185
DXR 0325 NA 325 2 in FNPT 460/3/60 2.3 kW 41 x 32 x 38 320
DXR 0400 NA 400 2 in FNPT 460/3/60 3.22 kW 41 x 32 x 38 349
DXR 0500 NA 500 2-1/2 in FNPT 460/3/60 3.22 kW 41 x 32 x 38 364
DXR 0600 NA 600 2-1/2 in FNPT 460/3/60 4.2 kW 41 x 32 x 38 362
DXR 0850 NA 850 3 in MNPT 460/3/60 (575/3/60 optional) 5.8 kW 55 x 45 x 40 507
DXR 1050 NA 1,050 3 in MNPT 460/3/60 (575/3/60 optional) 6.0 kW 63 x 44 x 40 717
DXR 1250 NA 1,250 3 in MNPT 460/3/60 (575/3/60 optional) 6.7 kW 63 x 44 x 40 745
DXR 1600 NA 1,600 4 in ANSI flange 460/3/60 (575/3/60 optional) 7.8 kW 72 x 44 x 40 860
DXR 1800 NA 1,800 4 in ANSI flange 460/3/60 (575/3/60 optional) 9.4 kW 72 x 60 x 40 1,019
DXR 2200 NA 2,200 4 in ANSI flange 460/3/60 (575/3/60 optional) 9.5 kW 72 x 60 x 40 1,120
DXR 2400 NA 2,400 4 in ANSI flange 460/3/60 (575/3/60 optional) 9.7 kW 72 x 60 x 40 1,120
DXR 3000 NA 3,000 6 in ANSI flange 460/3/60 (575/3/60 optional) 11.4 kW 78 x 57 x 72 1,786
DXR 3500 NA 3,500 6 in ANSI flange 460/3/60 (575/3/60 optional) 12.8 kW 78 x 57 x 72 1,797
DXR 4200 NA 4,200 6 in ANSI flange 460/3/60 (575/3/60 optional) 17.1 kW 78 x 57 x 72 1,985

Ratings are at 100 psig inlet, 100°F inlet air and 100°F ambient; dimensions are height x width x depth in inches, and 575 V three-phase is available from the 850 SCFM size up.

DXR Series Applications


DXR Series dimensional outline drawing

Footprints and connections across 27 sizes

Ten cabinet sizes, from a 42 lb wall-mountable box to a 1,985 lb floor unit.

The 10 to 30 SCFM units are boxes of about 18 x 14 x 20 in at 42 to 56 lb with 1/2 in NPT ports; the 50 and 65 SCFM units are 31 x 15 x 21 in at 113 lb with 1/2 in and 3/4 in FNPT; the 85 to 150 SCFM units are 32 x 19 x 23 in at 119 to 146 lb on 1 in FNPT; and the 185 to 250 SCFM units are 36 x 23 x 24 in at 170 to 185 lb on 1-1/2 in FNPT. The 325 to 600 SCFM sizes share a 41 x 32 x 38 in cabinet at 320 to 364 lb with 2 in and 2-1/2 in FNPT connections.

From 850 SCFM the dryer becomes a floor unit: 55 x 45 x 40 in at 507 lb with 3 in MNPT, then 63 x 44 x 40 in for the 1,050 and 1,250 SCFM units, 72 in tall with 4 in ANSI flanges from 1,600 to 2,400 SCFM at 860 to 1,120 lb, and 78 x 57 x 72 in with 6 in ANSI flanges for the 3,000, 3,500 and 4,200 SCFM units at up to 1,985 lb. All are air-cooled: leave the condenser face unobstructed, point the hot-air discharge away from the compressor intake, and keep the front clear for the drain and the panel.

Confirm the cabinet, the port position and the electrical service for your exact model with the quote; the outline above shows a mid-range unit.

Common FAQs

10 to 4,200 SCFM

  • Sizes: 27 models, 10 to 4,200 SCFM
  • Power: 115/1/60 to 150 SCFM, 230/1/60 at 185 and 230, 460/3/60 from 250 SCFM (575 V optional from 850)
  • Connections: 1/2 in NPT to 6 in ANSI flange
  • Refrigerant: R513A to 65 SCFM, R410A from 85 SCFM
  • Max inlet pressure: 203 psig (232 psig on the 10 to 30 SCFM units)
  • Max inlet temperature: 131°F; 140°F from 325 SCFM up
  • Max ambient: 115°F
  • Pressure dew point: 38°F, ISO 8573-1 class 4-5
  • Cooling: Air-cooled