AES Series Digital Scroll Refrigerated Air Dryers

PRODUCTTYPEFLOWRATING
Refrigerated Air DryerDigital Scroll Cycling600 to 10,000 SCFM232 psig / 120°F inlet

Specifications


Configuration & Size

Sizes:
18 flows, 600 to 10,000 SCFM, each as -A air-cooled or -W water-cooled
Power:
460/3/60; 5.5 to 87.6 kW air-cooled (other voltages optional)
Connections:
3 in NPT to 1,250 SCFM, 4 in flanges at 1,500 to 2,000, 6 to 12 in flanges above
Refrigerant:
R-404A

Features

  • The scroll set unloads for a portion of each cycle, so capacity follows demand smoothly from full load down to a trickle
  • No stored thermal mass to charge and discharge, and no hot-gas bypass wasting compressor work at part load
  • Dew point holds at 38°F whether the plant is at 100 percent or 25
  • Air-cooled A and water-cooled W builds carry the same flow ratings

Ratings

  • Inlet pressure: 0 to 232 psig
  • Inlet and ambient: 40 to 120°F
  • Pressure dew point: 38°F, ISO 8573-1 class 5
  • Compressors: One digital scroll to 2,000 SCFM; two to five from 2,500 SCFM
  • Cooling: Air-cooled (A) or water-cooled (W), same flow ratings

Continuous modulation, not on-off

A digital scroll that unloads to the exact refrigeration the air needs

The AES Series is the digital-scroll cycling dryer for mid-size and central plants: eighteen flow sizes from 600 to 10,000 SCFM, each built air-cooled (A) or water-cooled (W). A digital scroll compressor modulates its capacity continuously, so refrigeration output tracks the air load and the dryer draws power in proportion to the work it does. From 2,500 SCFM the machine carries two to five scroll compressors on separate circuits, which gives redundancy as well as finer turndown, and a modular interface lets up to five dryers run together as one system. Connections run from 3 in NPT to 12 in flanges, and every size holds a 38°F dew point at 120°F inlet.

Multi-circuit machines from 2,500 SCFM. The AES-2500 runs two 6 hp scrolls; the AES-10000 runs five 10 hp scrolls, each on its own circuit; One circuit down for service leaves the others drying air, which a single-compressor dryer cannot offer; A modular interface lets up to five AES dryers share the load as a single plant dryer; Standard 460 V three phase, with other voltages available on request.

How the sizes step up. 600, 800, 1,000, 1,250, 1,500, 1,750 and 2,000 SCFM on single compressors of 3 to 10 hp, drawing 5.5 to 17.5 kW; 2,500 to 4,000 SCFM on two compressors, 4,500 to 6,000 on three, 7,000 and 8,000 on four, 8,750 and 10,000 on five; A 300 hp plant delivering 1,350 SCFM lands on the AES-1500; a 1,000 hp plant at 4,500 SCFM on the AES-4500.



AES Series refrigerated air dryer close-up

Fine steps below 2,000 SCFM, multi-circuit above

Request a Quote

AES Series Part Numbers

Part Number SCFM Connection Voltage Power Dimensions (in) Weight (lb)
AES-600A 600 3 in NPT 460/3/60 5.48 kW 45 x 34 x 45 645
AES-800A 800 3 in NPT 460/3/60 6.55 kW 48 x 38 x 54 805
AES-1000A 1,000 3 in NPT 460/3/60 7.81 kW 48 x 38 x 54 810
AES-1250A 1,250 3 in NPT 460/3/60 9.49 kW 48 x 38 x 54 860
AES-1500A 1,500 4 in flange 460/3/60 11.49 kW 84 x 58 x 41 1,650
AES-1750A 1,750 4 in flange 460/3/60 14.88 kW 84 x 58 x 41 2,250
AES-2000A 2,000 4 in flange 460/3/60 17.53 kW 84 x 58 x 41 2,300
AES-2500A 2,500 6 in flange 460/3/60 18.98 kW 52 x 114 x 65 2,370
AES-3000A 3,000 6 in flange 460/3/60 22.98 kW 110 x 124 x 44 3,980
AES-3500A 3,500 6 in flange 460/3/60 29.75 kW 110 x 124 x 44 5,180
AES-4000A 4,000 6 in flange 460/3/60 35.06 kW 110 x 124 x 44 5,258
AES-4500A 4,500 8 in flange 460/3/60 36.46 kW 102 x 186 x 44 6,408
AES-5250A 5,250 8 in flange 460/3/60 46.63 kW 102 x 186 x 44 8,208
AES-6000A 6,000 8 in flange 460/3/60 54.58 kW 102 x 186 x 44 8,358
AES-7000A 7,000 10 in flange 460/3/60 59.5 kW 109 x 247 x 44 11,623
AES-8000A 8,000 10 in flange 460/3/60 70.11 kW 109 x 247 x 44 11,823
AES-8750A 8,750 12 in flange 460/3/60 74.38 kW 111 x 308 x 47 15,528
AES-10000A 10,000 12 in flange 460/3/60 87.64 kW 111 x 308 x 47 15,778
AES-600W 600 3 in NPT 460/3/60
AES-800W 800 3 in NPT 460/3/60
AES-1000W 1,000 3 in NPT 460/3/60
AES-1250W 1,250 3 in NPT 460/3/60
AES-1500W 1,500 4 in 460/3/60
AES-1750W 1,750 4 in 460/3/60
AES-2000W 2,000 4 in 460/3/60
AES-2500W 2,500 6 in 460/3/60
AES-3000W 3,000 6 in 460/3/60
AES-3500W 3,500 8 in 460/3/60
AES-4000W 4,000 8 in 460/3/60
AES-4500W 4,500 8 in 460/3/60
AES-5250W 5,250 8 in 460/3/60
AES-6000W 6,000 8 in 460/3/60
AES-7000W 7,000 10 in 460/3/60
AES-8000W 8,000 10 in 460/3/60
AES-8750W 8,750 12 in 460/3/60
AES-10000W 10,000 12 in 460/3/60

Ratings are at 100 psig, 100°F inlet and 100°F ambient; the A and W suffixes are the air- and water-cooled builds, dimensions are height x width x depth, and the water-cooled power, dimensions and weight are stated on the quote for the specified cooling water.

AES Series Applications


AES Series dimensional outline drawing

Footprints from a single cabinet to a 25 ft machine

Air-cooled dimensions; water-cooled units are quoted for the site.

The AES-600A is a 45 x 34 x 45 in cabinet at 645 lb; the 800, 1,000 and 1,250 SCFM units share a 48 x 38 x 54 in cabinet at 805 to 860 lb, all on 3 in NPT. The 1,500 to 2,000 SCFM units are 84 x 58 x 41 in at 1,650 to 2,300 lb on 4 in flanges. From 2,500 SCFM the machine widens: 52 x 114 x 65 in for the AES-2500A, 110 x 124 x 44 in for the 3,000 to 4,000 SCFM units at 3,980 to 5,258 lb on 6 in flanges, 102 x 186 x 44 in for 4,500 to 6,000 SCFM on 8 in flanges, 109 x 247 x 44 in for 7,000 and 8,000 SCFM on 10 in, and 111 x 308 x 47 in for the 8,750 and 10,000 SCFM units at up to 15,778 lb on 12 in flanges.

Air-cooled units above 2,500 SCFM draw 19 to 88 kW and reject that power plus the heat pulled from the air into the room, so ventilation or a ducted discharge is part of the installation; the water-cooled W builds move that heat to the cooling tower and suit a hot or enclosed compressor room. Leave the full length of the machine accessible on the service side, pipe a bypass at line size, and route every drain to a condensate treatment unit.

Dimensions above are the air-cooled builds; a dimensional drawing for the exact model and cooling type, with flange heights and pad loads, accompanies each AES quote.

Common FAQs

600 to 10,000 SCFM

  • Sizes: 18 flows, 600 to 10,000 SCFM, each as -A air-cooled or -W water-cooled
  • Power: 460/3/60; 5.5 to 87.6 kW air-cooled (other voltages optional)
  • Connections: 3 in NPT to 1,250 SCFM, 4 in flanges at 1,500 to 2,000, 6 to 12 in flanges above
  • Refrigerant: R-404A
  • Inlet pressure: 0 to 232 psig
  • Inlet and ambient: 40 to 120°F
  • Pressure dew point: 38°F, ISO 8573-1 class 5
  • Compressors: One digital scroll to 2,000 SCFM; two to five from 2,500 SCFM
  • Cooling: Air-cooled (A) or water-cooled (W), same flow ratings