1701 Bypass Valves & Mounting Brackets bypass valve and mounting bracket, three-quarter view

1701 Bypass Valves and Wall-Mount Bracket Kits

PRODUCTTYPEFLOWRATING
Bypass Valve and Bracket KitsSingle-body bypass; wall brackets5 to 35 SCFM200 psig / 120°F

Specifications


Configuration & Size

Valves:
1701-1 non-bleed; 1701-3 bleed (current); 1701-2 bleed (earlier)
Connections:
3/8 in tube, dryer side; 3/8 in NPT, service side
Dryer brackets:
3153685 for 5 to 15 SCFM cabinets, 3219795 for 25 and 35 SCFM
Filter brackets:
23.4331-01 for housings 12 to 20, 23.4331-02 for 24 to 48

Features

  • Replaces two isolation valves, a bypass valve and four tees with one body and one handle
  • Bleed types (1701-3, 1701-2) depressurize the isolated dryer through an orifice, so the technician does not have to
  • Non-bleed 1701-1 keeps the isolated dryer or filter pressurized, for a quick filter change with no blow-down
  • Compression tube fittings with reusable rubber ferrules; nothing to solder or thread on the dryer side

Ratings

  • Max pressure: 200 psig
  • Max temperature: 120°F
  • Flow: 5 to 35 SCFM
  • Wetted parts: Brass, nylon and Buna-N
  • Size: About 4-5/8 x 3-1/4 x 2 in, 0.5 lb

One valve instead of three

Isolate the dryer for service without stopping the air

The 1701 is a single-body bypass valve for a small refrigerated dryer or filter. One handle does the work of three ball valves and their tees: turn it and the dryer is isolated for service while air keeps flowing. Three versions share a brass and nylon body with 3/8 in tube fittings toward the dryer and 3/8 in NPT toward the line. The 1701-1 is the non-bleed type and leaves the isolated dryer under pressure; the 1701-3 and the earlier 1701-2 are bleed types that vent it in bypass. Rated 200 psig and 120°F, 5 to 35 SCFM. Bracket kits for the small dryers and filter housings are listed with it.

Bracket kits for dryers and filter housings. 3153685 hangs the 5, 10 and 15 SCFM cabinet dryers; 3219795 hangs the 25 and 35 SCFM cabinets; 23.4331-01 bolts to the head of housings 12, 16 and 20 with four screws; 23.4331-02 fits housings 24 through 48; Filter brackets carry the housing weight so a prefilter, dryer and afterfilter train no longer hangs on the pipe; Dryer brackets are the bracket only; wall anchors are chosen for the wall.

For the 5 to 35 SCFM cabinet dryer. A 25 SCFM dryer behind a 5 hp piston compressor takes a 1701-3, piped to the dryer ports with 3/8 in tube, and the 3219795 bracket; Above 35 SCFM a conventional three-valve bypass in the pipe size of the dryer is built from ball valves and tees; Confirm the bracket fit for the current 7 to 50 SCFM cabinets with the quote; the kits are listed by the earlier cabinet sizes.



1701 Bypass Valves & Mounting Brackets bypass valve and mounting bracket close-up

The dryer, the bypass and the bracket ordered together, so the holes and the tubing line up

Request a Quote

1701 Bypass Valves & Mounting Brackets Part Numbers

Part Number Connection For Rating
1701-1 3/8 in tube (dryer side) x 3/8 in NPT (service side) Non-bleed type 200 psig
1701-2 3/8 in compression tube x 3/8 in NPT Bleed type 200 psig
1701-3 3/8 in OD tube x 3/8 in FNPT Bleed type, current part; Sold for HPR series dryers 200 psig
3153685 fits HPR5-10 and HPR15 dryers Wall mount bracket, HPR 5-10 and 15 200 psig
3219795 fits HPR25 and HPR35 dryers 200 psig
23.4331-01 fits HF-12, HF-16, HF-20 housings Also fits some HDF desiccant filters 200 psig
23.4331-02 fits HF-24 through HF-48 housings 200 psig

The valves are rated 200 psig and 120°F at 5 to 35 SCFM; the bracket part numbers are listed by the dryer cabinet or filter housing they fit.

1701 Bypass Valves & Mounting Brackets Applications


1701 Bypass Valves & Mounting Brackets dimensional outline drawing

Dimensions and mounting

A 4-5/8 x 3-1/4 x 2 in body in the line ahead of the dryer, tubes to the dryer, pipe to the shop.

The valve body sits in the supply line at the dryer, with the 3/8 in NPT ports toward the compressor and the shop and the two 3/8 in tube fittings toward the dryer inlet and outlet. The tubes run short and direct to the dryer connections on the back panel; keep them free of tight bends so the ferrules seal square. Mount the body where the handle can be reached with the dryer in place, and label the handle positions, because a dryer left in bypass for a month is the usual reason a shop suddenly has water in the lines.

On a bleed valve, the orifice vents the isolated dryer to the room when the handle goes to bypass; point it away from the technician and away from the electrical panel. The dryer brackets fasten to the back of the cabinet and hang it on the wall with the condenser grille clear of the wall by the depth of the bracket; leave 12 in above and behind for air. The filter brackets bolt to the filter head, and the housing then hangs with its bowl clear of the wall for element changes.

Confirm the valve version, the bracket kit and the dryer cabinet with the quote; the drawing above is representative of the 1701 body.

Common FAQs

5 to 35 SCFM

  • Valves: 1701-1 non-bleed; 1701-3 bleed (current); 1701-2 bleed (earlier)
  • Connections: 3/8 in tube, dryer side; 3/8 in NPT, service side
  • Dryer brackets: 3153685 for 5 to 15 SCFM cabinets, 3219795 for 25 and 35 SCFM
  • Filter brackets: 23.4331-01 for housings 12 to 20, 23.4331-02 for 24 to 48
  • Max pressure: 200 psig
  • Max temperature: 120°F
  • Flow: 5 to 35 SCFM
  • Wetted parts: Brass, nylon and Buna-N
  • Size: About 4-5/8 x 3-1/4 x 2 in, 0.5 lb


1701 Bypass Valves & Mounting Brackets Units